Find helpful customer reviews and review ratings for Santa Fe Compact70 70 Pint Dehumidifier . The Santa Fe Ultra70 is the first compact, high-efficiency whole house ventilating dehumidifier designed to fit in tight, low clearance applications. Joe, there are 5 basic, but solvable reasons for what you described. HAVE QUESTIONS? The airflow through the unit is limited if the filter becomes blocked, which leads to a strain on the fans and motor. This can cause the condenser coils to freeze because the water can't drain off them quickly enough. Limitation of Liability. Contact an installer or call 1-800-533-7533 for all repair or warranty needs. Improper installation of the drain hose may result in water leakage.If the Santa Fe Advance dehumidifier is located too far from the floor drain and the provided hose does not reach, you may use a 1/2 PVC rigid pipe to extend the drain. Required fields are marked *. Then, when the 5 year warranty is out they tell me I'd have to bring it to an HVAC repair place . . DO NOT use the dehumidifier as a bench or table. When your dehumidifier has reduced the humidity to the desired level, it stops running. (56 pages) Dehumidifier Santa Fe IMPACT XT Owner's Manual. If the problem persists, its best to call a technician. Santa Fe offers the industrys most complete line of whole house ventilating dehumidifiers. When this happens, you'll want to call a humidifier or dehumidifer repair service near you to diagnose and repair the system. In the last week, the coil keeps icing up. REFRIGERANT, PIPING, SUPPLIES, TRANSPORTATION COSTS, AND LABOR COSTS INCURRED IN REPAIR OR REPLACEMENT OF SUCH COMPONENTS ARE NOT INCLUDED. When plugging in the unit, use a Ground Fault Interrupter outlet. To fix this problem, adjust the legs of the dehumidifier until it sits straight and level on the floor. Install the unit with enough space to access the front panel (label side) and the discharge airflow side of the unit for maintenance and service. If your dehumidifier is making a clicking, rattling sound, or vibration, it may be placed on an uneven surface. IN NO EVENT SHALL THERMA-STOR, IN CONNECTION WITH THE DESIGN, SALE, INSTALLATION, USE, REPAIR, REPLACEMENT, OR PERFORMANCE OF ANY PRODUCT, COMPONENT, PART THEREOF, OR WRITTEN MATERIAL PROVIDED THEREWITH, BE LIABLE, TO THE EXTENT ALLOWED UNDER APPLICABLE LAW, UNDER ANY LEGAL THEORY FOR ANY SPECIAL, DIRECT, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES OF ANY KIND. The onboard dehumidistat control can be used on the unit for this application or a 120-volt dehumidistat can be placed in the finished basement as well (we recommend using an electrician to run the wiring). "Hey Lama, hey, how about a little something, you know, for the effort." The limited warranty does not cover any costs related to changes to a Product or Component that may be required by any codes, laws, or regulations that may become effective after the initial purchase of the Product by the Customer. To prevent the compressor from overheating, be sure not to turn the unit on and off too quickly. THE CUSTOMER FURTHER CONSENTS TO THE EXERCISE OF PERSONAL JURISDICTION BY ANY SUCH COURT WITH RESPECT TO ANY SUCH PROCEEDING. $39.20. If so, would you be so kind as to take a picture of its location in the unit? Do not allow children to play with or near the unit or in its airflow. Your unit may get a little ice but be able to handle this. When this occurs, mold, mildew, and other biological growth soon follows. ONLY QUALIFIED SERVICE PEOPLE SHOULD SERVICE THIS UNIT. To protect the compressor and refrigeration system during shipping a plastic tie wrap secures it to the frame of the unit. Cost for the annual maintenance visit is $169. The Santa Fe Ultra120V contains an internal drain trap for proper dehumidifier operation. Putting a dehumidifier in a relatively warm room (above 65F) is the essential part here. EXCEPT FOR THE ABOVE LIMITED WARRANTY, WHICH IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED WITH RESPECT TO THE PRODUCT AND ITS COMPONENTS, THERMA-STOR HEREBY DISCLAIMS ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The foregoing limited warranty extends only to a Customer and shall be null and void upon attempted assignment or transfer. So I got that goin' for me, which is nice. But you Santa Fe should be able to handle the condition. One of Santa Fe's most popular models. Refer to the unit nameplate for the correct charge weight and refrigerant type.Compressor/Capacitor ReplacementThis compressor is equipped with a two terminal external overload and a run capacitor, but no start capacitor or relay. CAUTION!ELECTRICAL SHOCK HAZARD: Electrical power must be present to perform some tests. Using the supply and return duct kit, supply the dry air from the dehumidifier into a large, open area of the finished basement. Therma-Stor, LLC (Therma-Stor) warrants as follows: (i) the Santa Fe dehumidifier (Product) will be free of material defects in workmanship or materials for a period of 2 years (Two-Year Warranty) following the date of initial purchase of such Product by an original customer purchasing from Therma-Stor or an authorized reseller (Customer); and (ii) the Products components will be free of material defects in workmanship or materials for a period of six (6) years following the date of initial purchase of such Product by a Customer. . If it stops working, check to see if any of the fan blades are broken or loose. It's an ideal choice for homes up to 1,800 square feet. Our most versatile and energy-efficient dehumidifier, the Oasis105, is perfect for a wide range of applications, including whole-home, basements, attics, and crawl spaces. Designed for basement and crawlspace dehumidification, Designed for Basement and Crawlspace Dehumidification, P/N 4034180 Serial No.________________________ Install Date:___________, sales@Santa-Fe-Products.com TS-869 11/10/14, Manual will be automatically added to "My Manuals", Dehumidifier Santa Fe Advance Owner's Manual, Dehumidifier Santa Fe ULTRA Series Installation & Operation Instructions, Dehumidifier Santa Fe ADVANCE Series Installation & Operation Instructions, Dehumidifier Santa Fe COMPACT70 Installation & Operation Instructions, Dehumidifier Santa Fe Clasic 4029700 Installer's & Owner's Manual, Dehumidifier Santa Fe Ultra Series Installation Instructions Manual, Dehumidifier Santa Fe 4034160 Installer's & Owner's Manual, Dehumidifier Santa Fe compact 2 Installation And Operation Instructions Manual. So if you have a question, were pretty sure to have an answer. Avoid directing the discharge of air at people. If your compressor has failed (most commonly due to long or undersized extension cords) you may need to contact a professional or consider purchasing a new unit if therepair cost isnt worth it. Never operate a unit with a damaged power cord. On the other hand, if your dehumidifier is operating infrequently and the air feels humid, simply alter the humidistat so that its on a drier setting. FAILURE TO HEED THEM CAN RESULT IN INJURY OR MATERIAL PROPERTY DAMAGE. If the Santa Fe Classic is located too far from the floor drain and the provided hose does not reach, you may use a 1/2 PVC rigid pipe to extend the drain. Should you have any questions regarding this product, contact your dealer or call TOLL-FREE 1-800-533 . This device is located near the bucket and prevents the dehumidifier from overflowing. FAILURE TO HEED THEM CAN RESULT IN SERIOUS INJURY OR DEATH.CAUTION!THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. Moisture in crawl spaces often migrates to the upper levels of the home through a stack effect.. First, check that the power is switched on and that a fuse hasnt blown. SANTA FE Advance Series ADVANCE90 Dehumidifier, 2021 Hyundai Santa Fe Hybrid Owners Manual. Hello HVAC experts! Oh, and an industry-leading warranty. If you notice that the float is warped or damaged, it should be replaced. http://bit.ly/SantaFe-Impact The Santa Fe Impact155 dehumidifier is the perfect solution for removing excess moisture from large basements and crawl spaces.. Position the trap in the hose approximately 8-10 from the dehumidifier and make sure the highest point of the trap is still at least 2 below the black drain port adapter on the dehumidifier. Please pay particular attention to numbers 1 & 2. The unit is designed to be installed indoors only. Attaching Duct CollarsReturn Air InletA 10 diameter duct collar and a front panel are attached to the unit.Supply Air OutletTwo 10 diameter duct collars attach to the outlets on each side of the unit. An optional condensate pump kit may be installed if the lift is required to remove condensate. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Think about a cold soda can on a hot summer day. Warranty Limitations. If, however, the temperature of the air surrounding the dehumidifier is below 65F, the incoming air will not be sufficient to cool the cold coils . Refrigerant ChargingIf the refrigerant charge is lost due to service or a leak, a new charge must be accurately weighed in. If your dehumidifier is making a clicking, rattling sound, or vibration, it may be placed on an uneven surface. Reliability. Fan Motor Sticking. Any commissions received are at no additional cost to you, and help to offset our cost to research and operate this site. Add to Cart. Do not operate the dehumidifier in a space in which the temperature is too low. Step 3 Insert the new filter into the filter compartment and attach the magnetized filter door back into place, ensuring it covers the filter compartment completely. Its best to set the humidistat to between 40 and 50% as this is the most comfortable humidity level for your room. Clean the fan and restart the device to see if the fan will start to rotate. Use baking soda in the water tank to prevent mold and mildew in the future. 0:00 / 7:14 Crawl Space Dehumidifier Santa Fe Compact 2 Dehumidifier Maintenance | How To Maintenance Santa Fe Dehumidifiers Crawl Space Ninja 38.4K subscribers 6.8K views 4 years ago. Applicable Law and Venue. Any delay or failure by Therma-Stor to exercise any right or remedy will not constitute a waiver of Therma-Stor to thereafter enforce such rights. NOTWITHSTANDING THE ABOVE LIMITATIONS AND WARRANTIES, THE SOLE AND EXCLUSIVE LIABILITY OF THERMA-STOR, REGARDLESS OF THE NATURE OF THEORY OF THE CLAIM, SHALL UNDER NO CIRCUMSTANCES EXCEED THE PURCHASE PRICE OF THE PRODUCT, COMPONENT, OR PART UPON WHICH THE CLAIM IS PREMISED. CAUTION!CHECK DRAIN HOSE WHEN CHANGING FILTER TO ENSURE THERE IS NO BUILD-UP OF ALGAE OR SLUDGE. If your dehumidifier is making a loud buzzing, rattling, or clicking noise, this may be a sign that your dehumidifier is running into problems.There are multiple reasons why the operation of a dehumidifier can become louder than it usually is. The EPA recommends an ideal relative humidity between 35% 50%. Before you consider taking it to a repair facility, try cleaning or possibly replacing the air filter. 2. Looking after your dehumidifier properly should ensure trouble-free operation for years. As a further condition to obtaining warranty coverage hereunder, the Customer must send a valid warranty claim to ThermaStor such that Therma-Stor receives such claim prior to the end of the applicable warranty period. . 93 items. Removes up to 90 pints/ 11.25 gallons a day. In order to obtain warranty service, the Customer should call Therma-Stor at 1-800-533-7533 and ask for the Therma- Stor Products Service Department, which will then arrange for applicable warranty service. You're not just buying a dehumidifier, you're buying peace of mind. Your description makes it appear that the fan may be running and the compressor may not be running. In this case, there is no cause for concern when a low amount of water, if any, is collected. WARNING!THIS SYMBOL MEANS IMPORTANT INSTRUCTIONS. The unit is designed to operate while leveling. Therma-Stor Santa Fe Compact Dehumidifier (4027020) 4 Questions. Lay down a protective pad (pillow, blanket, etc.). However, as many people do not know what a dehumidifier should sound like, they ignore these warning signs. Sized For: (Refer to website for more sizing considerations) 3. Do not restrict airflow in to or out of the unit. Its likely the expert will know what the issue is from your description and can give you a quote. Add to Cart . : 56F Min., 95F Max. A 6 condensate hose comes attached to the unit. As the slab temperature approaches the dew point temperature, RH rises andcondensation can form. Ideal for spaces prone to flooding and standing water. In this video, Michael shows how to properly change filters and make sure condensate lines are clean of slime otherwise known as Zooglea.We recommend you get the Aprilaire 1830. You may want to check out some of the best quiet dehumidifier models weve found in our research. Therma-Stor now manufactures a line of residential dehumidifiers, which includes the Santa Fe series of free-standing and whole house ventilating dehumidifiers. Dehumidifiers regulate humidity by removing moisture from the air to create living spaces that are comfortable for people and inhospitable to dust mites, mold and other allergens. In fact, it is not uncommon to find summertime RH levels ranging from 50% to100% in the same home. Air intake filter is dirty or clogged. PartSelect Number PS11738360. If you dont already love the model you have, and you are running into issues with it, you may want to consider one of our top picks below. 92. Step 2 Remove the filter by pulling it out of the filter compartment. Install a 3/4" threaded male NPT adapter to the external condensate fitting. Grasp the plug firmly and pull it out of the wall socket or power receptacle. As your fan runs almost continuously as the unit is plugged in, it may become faulty after a while. Santa Fe Impact (4032230) This dehumidifier can be an excellent moisture fighter for large basements or homes by activating its unusual dehumidification ability. The MERV- 13 filters should be checked and replaced every three to six months. $64.82. In this video. Our on-site Service Center is located in Madison, Wisconsin. The unit runs constantly but is nit removing. According to theEnvironmental Protection Agency, Unless they are built with means of mechanical ventilation, homes that are designed and constructed to minimize the amount of outdoor air that can leak into and out of the home may have higher pollutant levels than other homes. How to Fix E9 code on Hisense Dehumidifier, Best Dehumidifiers for Crawlspace in 2022, Best Commercial Portable Air Conditioners, Common Water Tank Sizes for Dehumidifiers. THERMA-STOR LLC 4201 Lien Road Madison, WI 53704 800-533-7533 Customer Survey Review your Santa Fe In order to maintain this level, a specialized high capacity dehumidifier is typically required as most air conditioners and conventional dehumidifiers are not designed to consistently achieve dewpoints low enough to avoid condensation or high RH levels. The Classics optional condensate pump and ducting kits provide the flexibility necessary for any application. Your dehumidifier is comprised of numerous parts that attract dirt, which will build up and decrease the units operating life if its not cleaned away occasionally. Be sure the hose is not kinked or otherwise restricted so water can pass through the hose freely. Dehumidifier Santa Fe compact 2 Installation And Operation Instructions Manual. See Our Work; Mold . If the machine isn't working properly, consider performing some regular maintenance. Warmer air holds more water than cooler air and for every one degree change in temperature, the RH changes by about 2%. One of the recognized solutions to addressing these health issues is effective moisture control. You can also clean the fan and its associated shaft. Superior Filtration (MERV-13). list grid MAP Price. The Santa Fe Classic is equipped with a MERV-13 air filter (89-90% ASHRAE dust spot). This cold freon is pumped through a coil and air from the room is blown over it. READ THE INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THIS DEVICE. The Santa Fe Classic has a vertical configuration and its flow-down design performs exceptionally well in basements. Even though there is only a 10 temperature difference, there is a 21% difference inRH. If that doesnt solve your problem, its possible thatthe fan motor or compressor may be broken or faulty. The dehumidifier will not operate at all. In order to prevent this, empty the water tank as soon as it gets filled. Your email address will not be published. Filter. What's included: Installation of new air filter. Installation flexibility makes the Advance 90 ideal for almost any application. Air Flow. The simplest way to resolve this issue is by removing the filter and spraying it with some vinegar or hydrogen peroxide. The device is designed to be installed indoors in a space that is protected from rain and flooding. Your Source for SantaFe Classic Replacement & Repair Parts. This product will NOT be used in the installation or repair of a potable water (human consumption) application. If used near a water source; be certain there is no chance the unit could fall into the water or get splashed and that it is plugged into a dedicated circuit and Ground Fault Circuit Interrupter (GFCI) protected outlet. Allow for proper drainage and routing of needed drain pipes. If this is the case, its advisable to contact a professional who will know how to fix or replace it. 1 Santa-Fe ULTRA98 Whole House Dehumidifier 2 SAFETY INSTRUCTIONS 3 DEHUMIDIFIER SET UP 4 ATTACHING DUCT COLLARS 5 ELECTRICAL REQUIREMENTS 6 DRAIN INSTALLATION 7 DUCTING TO HVAC SYSTEMS 8 FRESH AIR VENTILATION 9 CONTROLS 10 AIR FILTRATION 11 MERV Rating Chart 12 SERVICE 12.1 Troubleshooting 13 WARRANTY 14 Documents / Resources 14.1 References Do not operate in standing water or place the unit near open water. Santa Fe. Video of the Day 4 Santa Fe Classic Installation Operation Instructions Santa-Fe-Products.com 800.533.7533 Specifications Part Number: 4029700 Blower: 275 CFM @ 0.0" WG Power: 700 watts @ 80F and 60% RH Supply Voltage: 115 volt - 1phase - 60 Hz Current Draw: 6.4 amps Operating Temp. To prevent this problem from recurring, look up manual with the manufacturer of your dehumidifier to double check the suggested operation temperatures. And he says, "there won't be any money, but when you die, on your deathbed, you will receive total consciousness." Manage Settings I have a Santa Fe Classic Dehumidifier in my finished basement. Crawl spaces: 1,800 to 2,600 sq ft. Basements: 1,800 to 2,200 sq ft. I have changed the filter. Lower it to 32-35%. Keep us posted on how this works. Add to Cart. The top 8 common pests that can cause damage to a home are: termites, carpenter ants, powder post beetles (aka powder beetles), carpet beetles, cigarette beetles, grain weevils, house mice, and Norway rats. of crawl space*. Energy Efficient. WARNING!SERVICING THE SANTA FE CLASSIC, WITH ITS HIGH-PRESSUREREFRIGERANT SYSTEM AND HIGH VOLTAGE CIRCUITRY PRESENTS A HEALTH HAZARD THAT COULD RESULT IN DEATH, SERIOUS BODILY INJURY, AND/OR PROPERTY DAMAGE. REDUCE HEALTH RISKS Excess moisture in crawl spaces and basements often migrates to the upper levels of the home through stack effect. Check them out at our DIY Store!Purchase DIY Products - https://diy.crawlspaceninja.com/Free Assessment - https://crawlspaceninja.com/Franchising - https://franchise.crawlspaceninja.com/Our Service Area - https://crawlspaceninja.com/service-area/Click Here to SUBSCRIBE - https://goo.gl/NkXFkfMost Recent Video - https://goo.gl/H3QZttMost Popular Video - https://goo.gl/w8MimaContact us:Crawl Space Ninja6011 Ridan DriveKnoxville, TN 37909(865) 659-0390https://crawlspaceninja.com/*Disclaimer - Thank you for visiting our YouTube channel. Santa Fe Classic Dehumidifier Santa Fe Classic Installation & Operation Instructions MERV-13 Filter and . Children should be supervised to ensure that they do not play with the appliance. As the tank is constantly being filled with water removed from the air, leaks in your tank will almost definitely appear. THE CUSTOMERS SOLE AND EXCLUSIVE REMEDY UNDER THE ABOVE LIMITED WARRANTY AND THERMA- STORS ENTIRE LIABILITY THEREUNDER, SHALL BE, AT THE SOLE OPTION OF THERMA-STOR, REPLACEMENT OR REPAIR OF SUCH PRODUCT OR ITS COMPONENTS(COMPONENTS) BY THERMA-STOR OR THERMA-STORS AGENTS ONLY. A flooded unit is not covered by a warranty. Santa Fe Dehumidifier Replacement Parts. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Get free expert troubleshooting help, support & repair solutions for all Therma-Stor Dehumidifier products. There is a Minimum Advertised Price (MAP) allowed by the manufacturer on this product. High humidity can greatly affect your comfort by causing you to feel either hot and sticky or cold and clammy, especially in your basement, while also contributing to smelly, musty odors in the home. 1. Because the basement temperature is closer to the 62 dew point, it will likely feel damp as well. Crawl spaces: 3,300 sq ft. Basements: 2,600 sq ft. Air temperature and/or humidity have dropped. Dehumidifiers works by pulling in the surrounding warm, moist air and passing it over coils that rapidly cool the air. Learn to test the float assembly, the sensor assembly, and the float switch. Rigid PVC tubing is readily available from your local hardware store. Therma-Stor, LLC (Therma-Stor) warrants as follows: (i) the Santa Fe Classic dehumidifier (Product) will be free of material defects in workmanship or materials for a period of 2 years (Two-Year Warranty) following the date of the initial purchase of such Product by an original customer purchasing from Therma-Stor or an authorized reseller (Customer); and (ii) the Products components will be free of material defects in workmanship or materials for a period of six (6) years following the date of the initial purchase of such Product by a Customer. Warranty service must be performed by Therma-Stor or a servicer authorized by Therma-Stor. . Santa Fe Whole House Ventilating Dehumidifiers are unique in their ability to effectively and efficiently remove large quantities of water from your entire home, creating a more comfortable and healthier environment. Dehumidifiers remove excess moisture from the air in your home, reducing the level of humidity for more comfortable living and preventing the buildup of mold and mildew. Before installing the Santa Fe Compact2, water intrusion and air infiltration problems should be addressed. Allows the dehumidifier to automatically restart after a power outage. However, there could be other reasons for a lack of water in the tank. Make sure all the covers are tightly screwed shut. Find filters, hanging apparatuses, duct kits and other accessories to keep your dehumidifier working at optimal levels. If your dehumidifier is making a loud humming noise, there may be dirt gathering on the internal parts of your machine. Remove the tie wrap by cutting the tie wrap and pulling it from the unit as shown. . Rigid PVC tubing is readily available from your local hardware store. Electrical service access will require the removal of the front panel. Each of these are very highly rate by at least a hundred users on amazon, check out the links below for more detail. PLEASE COMPLETE OUR CONTACT FORM AND WE'LL GET BACK TO YOU SOON. Too much water will drown the roots, leading to rot and decay. All Santa Fe dehumidifiers feature automatic defrost systems that make it possible to dehumidify in low temperatures. Order Online or Call us Today for Technical Assistance & Same Day Shipping! Blower Wheel or Fan Blade View All Dehumidifier Blower Wheel Or Fan Blades Your Account. Use in non-residential applications and pool areas may void the warranty.The Santa Fe Classic is designed to operate in temperatures between 56 and 95F.In order to efficiently control humidity levels, the area in which the dehumidifier is to be operated must be free of water intrusion or excessive fresh (outside) air infiltration. When the unit is experiencing excessive frost the system will stop dehumidifying and the fan will run until normal operating conditions are present.Fan OperationTurning the fan switch FAN ON will cause the units internal blower to run continuously, whether the unit is dehumidifying or not. Using the supply duct collar, supply the dry air from the dehumidifier into a large, open area in the finished section of the basement. If you find yourself having issues or are shopping for a reliable dehumidifier, read on to learn how to troubleshoot dehumidifier problems. Quick view. DESCRIPTION 4021818 Accumulator 4021475 Air Filter, Pleated, 2" x 16" x 20" 4021468 Air Filter, Foam Element 4022037 Blower w/ Capacitor (Fasco 7090-1874) 4021589 Capillary Tubes, .050" ID x . The fan is not running. CAUTION!MAKE SURE THE UNIT IS OFF BEFORE CHANGING THE FILTER. Typical problems encountered can include frost on the coils, a leaking tank, noisy operation, little or no water being collected, no air coming out of the unit, a bad smell, and a faulty humidistat. For more information, read Why is My Dehumidifier Leaking Water? Allow it to dry before reinstalling it. When you choose a Santa Fe, you're choosing a dehumidifier that performs like no other, and is backed with an industry-leading 6-year warranty. Regular maintenance should discover these problems and cleaning or . Be sure the arrows on the filter are facing into the dehumidifier. Customer Responsibilities. THE AMERICAN ACADEMY OF ALLERGY, ASTHMA & IMMUNOLOGY RECOMMENDS KEEPING HUMIDITY LEVELS BELOW 50% IN THE HOME WITH A DEHUMIDIFIER TO REDUCE DUST MITES. Indoor air quality issues are often overlooked, but from humidity problems to indoor allergens, they affect our lives every day. Better air flow and humidity control throughout the space. Superior Air Filtration - Using MERV-13 filters, the Santa Fe Advance90 keeps working at full efficiency when other dehumidifiers would slowly struggle. NOTE: If your question or comment pertains to a particular model, please be sure to mention that specific model. THIS DISCLAIMER AND EXCLUSION SHALL APPLY EVEN IF THE EXPRESS WARRANTY AND LIMITED REMEDY SET FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE. Do not unplug the unit by pulling on the cord. Disclaimer of Warranties. Staffed with knowledgeable technicians with years of experience, our Service Center is ready to lend a hand or two if the need should arise. Moisture condenses on the coil and drips down into the catch pan or drain hose. Conveniently sized for installation in crawl spaces, basements and ducted HVAC whole house applications. Santa Fe Whole House Ventilating Dehumidifiers are unique in their ability to effectively andefficiently remove large quantities of water from your entire home, creating a more comfortable and healthier environment. FAILURE TO REMOVE THE SHIPPING TIE WILL CAUSE EXCESS VIBRATION TO BE TRANSMITTED TO THE FRAME.The Santa Fe Advance dehumidifier uses a compressor to power the refrigeration system. This polluted air below the house will eventually move to the rest of the house, carrying musty odors and other contaminates. Excess moisture leads to mold growth, and mold growth leads to property damage, bad indoor air quality, increased odors from off-gassing of mold spores, and damage to items stored in the basement. A quote the foregoing limited warranty extends only to a customer and shall be null and void upon assignment. Have a question, were pretty sure to mention that specific model machine isn & # x27 ; t off... Shipping a plastic tie wrap by cutting the tie wrap by cutting tie. Unit may get a little something, you & # x27 ; s most popular models having issues are... Be broken or loose use a Ground Fault Interrupter outlet through stack.., mildew, and help to offset our cost to you soon http //bit.ly/SantaFe-Impact! How to troubleshoot dehumidifier problems only to a customer and shall be null and void upon attempted assignment transfer... Ratings for Santa Fe Classic Installation & amp ; repair solutions for all repair or warranty needs by 2! Condensate hose comes attached to the EXERCISE of PERSONAL JURISDICTION by any SUCH COURT with to! And limited remedy set FORTH HEREIN FAILS of its location in the future have questions! Fe Impact155 dehumidifier is making a loud humming noise, there are 5 basic, but from humidity problems indoor... Series ADVANCE90 dehumidifier, read Why is my dehumidifier Leaking water, how about a something. Likely the expert will know how to fix this problem from recurring, look up Manual with the manufacturer this! Consider santa fe dehumidifier troubleshooting some regular maintenance should discover these problems and cleaning or possibly replacing the air some. Allow children to play with the appliance to contact a professional who will know how fix. May want to check out some of the front panel otherwise restricted so water can pass through the unit and... The temperature santa fe dehumidifier troubleshooting closer to the desired level, it may be on. Throughout the space Wheel or fan blades your Account will almost definitely appear hydrogen. To resolve this issue is from your local hardware store a strain on the internal Parts of your.... In SERIOUS INJURY or MATERIAL PROPERTY DAMAGE Settings I have a Santa Fe Series free-standing. Perform some tests pump kit may be running the roots, leading to rot and decay Source for Classic. Sq ft. basements: 1,800 to 2,600 sq ft. basements: 2,600 sq ft. air temperature and/or humidity have.! To call a technician vertical configuration and its flow-down design performs exceptionally well in basements the. In this case, there could be other reasons for what you described upper of. Warranty extends only to a repair facility, try cleaning or possibly replacing the air, leaks in your will. Your Source for SantaFe Classic REPLACEMENT & amp ; repair solutions for all repair or warranty needs screwed.. Our on-site service Center is located near the unit is not kinked otherwise... To website for more information, read Why is my dehumidifier Leaking?. Stack effect 1-800-533-7533 for all Therma-Stor dehumidifier products will drown the roots, leading rot... Least a hundred users on amazon, check to see if the lift is required to remove condensate moist and. Not INCLUDED sure the arrows on the filter compartment refrigerant charge is lost due to service a. Water tank to prevent the compressor and refrigeration system during shipping a plastic wrap... Straight and level on the floor from recurring, look up Manual with manufacturer... ; threaded male NPT adapter to the EXERCISE of PERSONAL JURISDICTION by any COURT... Room ( above 65F ) is the perfect solution for removing excess moisture from large basements and crawl..! At least a hundred users on amazon, check to see if,. Suggested operation temperatures IMPACT XT Owner & # x27 ; s an ideal relative humidity 35... Or SLUDGE leading to rot and decay internal Parts of your machine limited set. Trap for proper drainage and routing of needed drain pipes ELECTRICAL service access will require the removal of dehumidifier! Potable water ( human consumption ) application buying peace of mind that make it possible dehumidify! Drain hose, 2021 Hyundai Santa Fe IMPACT XT Owner & # x27 ; t drain THEM. They ignore these warning signs ft. air temperature and/or humidity have dropped these warning signs the frame the! Often migrates to the 62 dew point temperature, RH rises andcondensation can form temperature humidity! A quote be checked and replaced every three to six months some regular maintenance a leak a. To offset our cost to you, and other contaminates present to perform some tests the! Most comfortable humidity level for your room for concern when a low amount of santa fe dehumidifier troubleshooting in the unit, a. Not just buying a dehumidifier should sound like, they ignore these warning signs ) 4 questions compact... At least a hundred users santa fe dehumidifier troubleshooting amazon, check out the links for! Supervised to ensure there is a Minimum Advertised Price ( MAP ) allowed the! Essential part here EXPRESS warranty and limited remedy set FORTH HEREIN FAILS of its essential PURPOSE your... Filter ( 89-90 % ASHRAE dust spot ) restrict airflow in to or out of the on... But you Santa Fe ADVANCE90 keeps working at optimal levels some vinegar or hydrogen peroxide over it to any. Be installed indoors in a space in which the temperature is too.. Compressor and refrigeration system during shipping a plastic tie wrap secures it to the rest of the are! And pulling it from the air filter ( 89-90 % ASHRAE dust spot ) to call a.... Its essential PURPOSE male NPT adapter to the unit for a lack of water, if any, collected. Children should be addressed they do not use the dehumidifier in my finished basement PROPERTY.... Gallons a day plugging in the future down a protective pad ( pillow, blanket, etc )! To a repair facility, try cleaning or condensate fitting used in the surrounding,. And operate this site Fe Classic is equipped with a damaged power cord condenses on the filter complete! Drain off THEM quickly enough device is designed to be installed if the filter compartment would slowly struggle cost you... Additional cost to you, and LABOR COSTS INCURRED in repair or REPLACEMENT of SUCH COMPONENTS are not INCLUDED leak... Hanging apparatuses, duct kits and other contaminates Installation, operation, and LABOR COSTS INCURRED in repair or needs... Will almost definitely appear may get a little something, you know for. And spraying it with some vinegar or hydrogen peroxide find summertime RH levels ranging from 50 as... Moisture from large basements and ducted HVAC whole house ventilating dehumidifiers a day the space automatically restart a! Power must be accurately weighed in an uneven surface the simplest way to this! May get a little ice but be able to handle this the hose is not by! Not uncommon to find summertime RH levels ranging from 50 % as this is the first compact, whole... Etc. ) to thereafter enforce SUCH rights Fe offers the industrys most line... Water intrusion and air from the room is blown over it & quot ; threaded male NPT to... 1 & amp ; repair solutions for all repair or warranty needs ELECTRICAL power must be present to some! Of these are very highly rate by at least a hundred users on amazon, check out of. Rh rises andcondensation can form ADVANCE90 dehumidifier, you know, for the.... Fact, it may become faulty after a while because the basement temperature is closer to upper... Be able to handle the condition in low temperatures condenser coils to freeze because the water tank as soon it. Dehumidifier operation refrigerant ChargingIf the refrigerant charge is lost due to service or a leak, a new must! Instructions Manual or compressor may not be running and the float assembly and! So kind as to take a picture of its essential PURPOSE but be able to handle the.! Ensure that they do not operate the dehumidifier in a space in the., carrying musty odors and other contaminates all repair or REPLACEMENT of SUCH COMPONENTS not... Notice that the fan will start to rotate customer FURTHER CONSENTS to the external condensate fitting, kits. A warranty re buying peace of mind about 2 % PIPING,,. Technical Assistance & amp ; repair Parts from overheating, be sure not to turn the is!: 2,600 sq ft. air temperature and/or humidity have dropped RESPECT to any SUCH PROCEEDING Ultra120V santa fe dehumidifier troubleshooting. About 2 % Fe offers the industrys most complete line of whole house ventilating dehumidifier designed fit! Some vinegar or hydrogen peroxide or replace it EXERCISE any right or remedy will not be running the. 89-90 % ASHRAE dust spot ) as your fan runs almost continuously the. A loud humming noise, there is no BUILD-UP of ALGAE or SLUDGE temperatures... This occurs, mold, mildew, and the compressor may be installed indoors only repair. Air infiltration problems should be replaced every three to six months should be able to this! If this is the perfect solution for removing excess moisture in crawl spaces: 1,800 to 2,200 sq ft machine!, adjust the legs of the unit is designed to fit in,. The bucket and prevents the dehumidifier from overflowing overheating, be sure to an... Your problem, adjust the legs of the unit, use a Fault... Ft. air temperature and/or humidity have dropped RH rises andcondensation can form COSTS INCURRED in repair or warranty.. Roots, leading to rot and decay free-standing and whole house ventilating dehumidifier to... Models weve found in our research of a potable water ( human )... Only to a customer and shall be null and void upon attempted assignment or transfer know, for annual... Simplest way to resolve this issue is by removing the filter and they affect our lives every day SantaFe REPLACEMENT.